Allis-Chalmers LA-1600A Air Circuit Breaker Electrically Operated
Contact for Quote: 800-909-3660 | sales@naswgr.com
Allis-Chalmers LA-1600A Air Circuit Breaker Electrically Operated
Type: Power Circuit Breaker
Model: LA-1600A
Frame Size: 1600 Amp
Frequency: 60 HZ
Ampacity: 1600Amp Max
Voltage: 600 VAC
| Ratings: | ||
| Volts Max | AMP. SYMM. | Interrupting |
| INST. | Short Time | |
| 635 | 42000 | 42000 |
| 508 | 50000 | 50000 |
| 254 | 65000 | 5000 |
Additional Accessories:
Shunt Trip Group LA-600A/ LA-800A/ LA-1600A:
| Description | Part Number |
| Solenoid 48 VDC & 120 VAC | 18-724-513-001 |
| Solenoid 240 VDC & 125 VAC | 18-724-153-002 |
| Solenoid 24 VDC | 18-724-513-006 |
| Solenoid 250 VDC | 18-724-513-004 |
Motor Group LA-600A/ LA-800A/ LA-1600A:
| Description | Part Number |
| Motor 120 V.A.C. and 125 V.D.C | 71-340-297-001 |
| Motor 240 V.A.C. and 250 V.D.C | 71-340-297-002 |
| Motor 48 V.D.C | 71-340-297-005 |
Close Solenoid Group Incudes ANTI-PUMP "Y" Relay LA-600A/ LA-800A/ LA-1600A:
| Description | Part Number |
| Solenoid 48 VDC and 120 VAC | 18-724-513-001 |
| Solenoid 240 VDC and 125 VAC | 18-724-513-002 |
| Solenoid 250 VDC | 18-724-513-004 |
| Relay "Y" 120 VAC | 15-171-399-014 |
| Relay "Y" 240 VAC | 15-171-399-015 |
| Relay "Y" 125 VDC | 15-171-399-016 |
| Relay "Y" 250 VDC | 15-171-399-017 |
| Relay "Y" 48 VDC | 15-171-399-027 |
Alarm Switch Group, Bell Alarm LA-600A/ LA-800A/ LA-1600A:
| Description | Part Number |
| Solenoid 48 VDC | 18-724-497-005 |
| Solenoid 120 VAC | 18-724-497-001 |
| Solenoid 240 VAC | 18-724-497-003 |
| Solenoid 125 VDC | 18-724-497-002 |
| Solenoid 250 VDC | 18-724-497-004 |
Auxiliary Switch Group LA-600A/ LA-800A/ LA-1600A
Secondary Disconnect Group LA-600A/ LA-800A/ LA-1600A
Undervoltage Trip Group LA-600A/ LA-800A/ LA-1600A:
| Description | Part Number |
| 120 VAC Inst. Under-voltage | 18-391-885-801 |
| 240 VAC Inst. Under-voltage | 18-391-885-802 |
| 460 VAC Inst. Under-voltage | 18-391-885-803 |
| 120 VAC T.D. Inst. Under-voltage | 18-391-886-801 |
| 240 VAC T.D. Inst. Under-voltage | 18-391-886-802 |
| 460 VAC T.D. Inst. Under-voltage | 18-391-886-803 |
Static Trip Group LA-600A/ LA-800A/ LA-1600A:
| Description | Part Number |
| Type TI Static Trip | 18-468-194-501 |
| Type TS Static Trip | 18-468-194-502 |
| Type TSI Static Trip | 18-468-194-503 |
| Type TIG Static Trip | 18-468-194-504 |
| Type TSG Static Trip | 18-468-194-505 |
| Type TSIG Static Trip | 18-468-194-506 |
| Type TIG-T Static Trip | 18-468-194-507 |
| Type TSG-T Static Trip | 18-468-194-508 |
| Type TSIG-T Static Trip | 18-468-194-509 |
*Also Available with AC Pro Trip Units to Fit Your Application*
Tripping Current Transformer Group LA-600A/ LA-800A/ LA-1600A:
| Description | Part Number |
| Current Transformer 80/1 | 61-300-030-508 |
| Current Transformer 200/1 | 61-300-030-507 |
| Current Transformer 400/1 | 61-300-030-504 |
| Current Transformer 600/1 | 61-300-030-505 |
| Current Transformer 800/1 | 61-300-030-509 |
| Current Transformer 200/1 | 61-300-031-513 |
| Current Transformer 400/1 | 61-300-031-502 |
| Current Transformer 800/1 | 61-300-031-508 |
| Current Transformer 1600/1 | 61-300-031-505 |
Fuse Attachment Group LA-600A/ LA-800A/ LA-1600A:
| Description | Part Number |
| CL Fuse 800 Amp | 71-142-200-004 |
| CL Fuse 1000 Amp | 71-142-200-013 |
| CL Fuse 1200 Amp | 71-142-200-005 |
| CL Fuse 1600 Amp | 71-142-200-006 |
| CL Fuse 2000 Amp | 71-142-200-007 |
| CL Fuse 2500 Amp | 71-142-200-008 |
| CL Fuse 3000 Amp | 71-142-200-009 |
| CL Fuse 250 Amp | 71-142-200-001 |
| CL Fuse 400 Amp | 71-142-200-002 |
| CL Fuse 600 Amp | 71-142-200-003 |
| CL Fuse 800 Amp | 71-142-200-004 |
| CL Fuse 1000 Amp | 71-142-200-013 |
| CL Fuse 1200 Amp | 71-142-200-005 |
| CL Fuse 1600 Amp | 71-142-200-006 |
Anti-Single-Phase Device, Trigger Fuse Assembly
*Breaker Label/Style/Condition May Vary*
LA-1600A Air Circuit Breaker Only
Each LA-1600A Air Circuit Breaker is available "AS-IS" or NAS can provide "Cleaned & Tested" or "Class A Reconditioned"- Meggered, Ductored and Tested with Typed Report Backed by Our 1 Year Warranty. All additional accessories can be modified to fit your specific application.
Call 800-909-3660 or email sales@naswgr.com with questions.
After hours emergency hotline 216-570-2725
NASG16958, NASG16994, NASG16995 Location: SHIPPING CONTAINER 6, BLDG 6
NASG16962, NASG16966, NASG16967, NASG16970, NASG16974, NASG16977, NASG16978, NASG16982, NASG16983, NASG16984, NASG16985, NASG16988, NASG16989, NASG16990. NASG16991, NASG16992, NASG16997, NASG17000, NASG17001, NASG17002, NASG17004, NASG17005, NASG17032, NASG17038, NASG17050, NASG17053, NASG17054, NASG17072, NASG17087, NASG17090, NASG17096, NASG17097 NASG17098, NASG17099 Location: SHIPPING CONTAINER 5, BLDG 6
NASG16969, NASG16971, NASG16976, NASG16981, NASG16996, NASG16999, NASG17006, NASG17022, NASG17023, NASG17024, NASG17025, NASG17049, NASG17057, NASG17058, NASG17059, NASG17060 Location: BLDG 6
North American Switchgear, Inc. is an industry leader in the sale of new, used and out-of-production industrial circuit breakers, switchgear and associated parts. Our Cleveland, OH facility spans over 300,000 square feet and houses over 13,000 low and medium voltage circuit breakers from all major manufacturers. Aside from the sale of circuit breakers, switchgear and replacement parts, NAS also offers equipment recondition and repair services. For more information please visit our website at www.naswgr.com, call 800-909-3660 or email sales@naswgr.com. Visit our NAS website!